By Aqua Purification Systems, Inc.
International Wholesale Distributor
 
Digital Filter/Softener Valves
 

No Hard Water Bypass (1 & 1.25)

No Hard Water Bypass (1 & 1.25)

Plan the position of the no hard water bypass valve and control valve carefully because of the following:

• The 8’ no hard water bypass valve motor cable must be threaded through the back plate and connected to the two pin connector labeled DRIVE on the control valve board. Approximately 1’ of the cable length should be allowed for weaving through the back plate.
• The 15’ AC Adapter cable must be thread through the back plate of the control valve. Approximately 1’ of the cable length should be allowed for weaving through the back plate. The AC adapter should be installed to a properly grounded not switched outlet.

Try to allow suffi cient slack in cables so cables may be zip tied to plumbing lines to prevent the cables from being accidentally pulled. Where necessary, break out the tab in the back plate to allow two cables to be woven through the same slot in the back plate. No more than two cables may be woven through one back plate slot. To help prevent damage to cables, allow solder joints to cool or solvent cement joints to cure after completing the various service, drain and regenerant plumbing connections. Thread the various cables through the appropriate back plate(s)and connect as described in the bullets above.


Warning: file_put_contents(): Only 0 of 13785 bytes written, possibly out of free disk space in /home1/admin011/public_html/clackvalves.net/updates/concrete5.6.3.3/concrete/core/libraries/page_cache/types/file.php on line 62

Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0

Warning: Unknown: Failed to write session data (files). Please verify that the current setting of session.save_path is correct (/home1/admin011/public_html/clackvalves.net/files/tmp) in Unknown on line 0